EasyManua.ls Logo

IDEAL Evomax 120 - Frost Protection; Boiler Overheat Thermostat; Condensate Drain

IDEAL Evomax 120
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
EVOMAX -
User’s
To shut Down the Boiler
1. For short periods
Set the external controls to OFF. Wait 4 minutes and then
isolate the mains supply to the boiler.
2. For longer periods
Set the external controls to OFF. Switch the electricity
supply to OFF. For longer periods the entire system should
be drained, including the domestic hot water supply.
To Relight the Boiler
Rell the system if it has been drained, taking care to ensure no
air is in the boiler or system.
Repeat the procedure detailed in ‘To light the boiler’.
Frost Protection
The EVOMAX boiler has built into its control system the facility
to protect the boiler only against freezing.
Note.
This may not protect remote parts of the system, in which case
a separate frost thermostat should be tted.
Boiler Overheat Thermostat
Boiler overheating is detected by electrical sensors connected
to the boiler control module. If the boiler overheats it will shut
down and the display will show Overheat Lockout. Press the
reset button and the boiler will relight. If the fault recurs turn off
the boiler and consult a Gas Safe Registered Engineer or in IE
a competent person.
Condensate Drain
The condensate drain must not be modied or blocked.
Blockage of the condensate drain, caused by debris or freezing,
can cause automatic shutdown of the boiler or leakage from the
condensate trap mounted on the bottom of the boiler.
If freezing is suspected and the pipe run is accessible an attempt
may be made to free the obstruction by pouring hot water over
the exposed pipe and clearing any blockage from the end of the
pipe. If this fails to remedy the problem the assistance of a Gas
Safe Registered Engineer or in IE a competent person should be
sought.
Escape of Gas
Should a gas leak or fault be suspected contact your local gas
supplier without delay.
Do NOT search for gas leaks with a naked ame.
Cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains use a damp cloth and mild
detergent.
DO NOT use abrasive cleaning materials.
206210-3.indd 67 23/05/2011 09:47:14