11
ADVANCED FEATURES
B. TIMED PRE-HEAT
When Domestic Hot Water preheat is switched on at the boiler control the boiler will preheat during the timed
on central heating periods so as to provide more efcient water delivery. This function is disabled when the
preheat switch is set to off.
C. RTC (REAL TIME CLOCk) BACkuP
The electronic timer has a Real Time Clock which has a backup supply to maintain the date and time for when
power is removed from the boiler.
When power has been removed for more than 3 hours and is restored, it will be necessary to enter the date
and time again but the programmed periods will have been retained.