3.2.10 Mixing speed during operation
Speed:
15cm and lower can height = 230rpm
30cm and higher can height = 130rpm
3.2.11 Stop the operation manually
1. Push the Stop/Up key.
2. Wait until you hear a 'beep' and the display shows 'RDY !'
The door is unlocked.
3. If necessary, remove the can. See § 3.2.7.
3.2.12 Using the emergency stop switch
1. Push the emergency stop switch (A). The machine stops
immediately.
CAUTION
Only push the emergency stop switch in case
of a safety emergency. Do not use the
emergency stop switch as an on/off function!
2. Solve the problem as quickly as possible.
3. Release the emergency stop switch by turning the emergency
stop switch.
4. Turn on the machine. See § 3.2.3.
3.2.13 Restart the machine
1. Set the main switch to 'OFF'.
2. Wait 30 seconds.
3. Turn on the machine. See § 3.2.3.