DOC No: PN 86880 REV A
15
Recommended Parts (24 VDC Mains)
Resistor (38 KOHM) VISHAY CMF5038K300FHEB
Potentiometer (10 KOHM) VISHAY P16NP103KAB15
RED
YELLOW
BLACK
MANUAL CONTROL CONFIGURATION
To maintain protection of internal drive controller, your external
potentiometer should be tted with appropriate protection.
Manual Control
Install potentiometer and resistor (sized according to your voltage supply input)
across the red Power In and black Common lead wires. The potentiometer wiper
is connected to the white Speed Input lead wire. To increase speed, rotate the
potentiometer to increase voltage to the control line. To decrease speed, rotate
the potentiometer to decrease voltage to the control line.