DOC No: PN 86880 REV A
21
1
2
3
4
5
7
8
9
6
MODEL DEMSE
1
2
3
4
5
7
8
9
6
MODEL DEELE
LEAD FUNCTION BLACK CABLE WIRES DESCRIPTION
1 POWER RED +12 to +36 VDC, Class 2 (SELV),
Reverse-polarity protected
2 SPEED PWM IN YELLOW Ground if not used
3 GROUND BLACK Common isolated from motor housing
4 MOTOR CURRENT OUT BROWN Motor Current Out
5 FWD/REV ORANGE Forward (oat and insulate) Reverse
(ground)
6 FAULT OUT BLUE Fault Signal
7 TACH OUT GREEN 5 V square wave-2 pulses per revolution
8 SPEED 0-5 IN WHITE Control signal in, 0-5 VDC
9 SHIELD BARE Connected to Common
EAGLEDRIVE LEAD WIRE ASSIGNMENTS
Housed version PVC jacketed cable with SR-PVC insulated lead wires, 22 AWG (7/30)
per UL STYLE 2517, 105°C, 300V or Micropump-approved equivalent.