Filta-Max xpress Operator’s Guide
Introduction
The Filta-Max xpress* Pressure Elution Station is used to automate the elution of
Cryptosporidium spp. oocysts and Giardia spp. cysts from Filta-Max xpress* Filter Modules and
Filta-Max* Filter Modules.
The Pressure Elution Station and elution procedures are designed for use with 101,000 L water
samples.
Note: The recovery of Giardia spp. cysts from large-volume finished water samples may be affected
by residual chlorine in the sample.
1
Safety
For your safety, read this guide thoroughly before using the Filta-Max xpress Pressure Elution
Station.
IDEXX recommends that you perform your own safety assessments of the Filta-Max xpress
Pressure Elution Station and follow your own in-house health and safety guidelines.
All water samples, spills, splashes, aerosols, filters, and eluates should be handled with at least the
same precautions as the water source with regard to biohazards. The Pressure Elution Station does
not render such samples to be safe and, in fact, concentrates the biological risks into the eluate.
Ensure that the connections between the Filter Housings and any sampling equipment are capable
of withstanding the operating pressure of the elution station.
The Filta-Max xpress Pressure Elution Station weighs approximately 86 lb (38 kg). Be sure to use
a table or bench that can support the weight of the instrument. Two people are required to lift the
instrument. Do not use the pneumatic fittings that extend out of the back panel as a handle for
lifting. This will loosen the fittings and potentially introduce an air leak.
Ensure that you understand all instructions and safety precautions listed in this manual. If you have
any questions, contact IDEXX Technical Service as follows:
In the United States call +1 800 321 0207 or email watertechnicalservice@idexx.com.
In Europe call +44 (0)1638 676800 or email emeatechsupport@idexx.com.
Compliance
European Union: EN61010-1: 2010 and EN-2-040
US/MET NRTL Mark: UL 61010-1, 3rd Edition and UL 61010-2-040
Canada/MET “c” Mark: CSA C22.2 No. 61010-1. 3rd Edition and CSA C22.2 No. 61010-2-040
EN 61326-1:2013 PART 1: EU EMC Directive: EN 61000-4-3 Radiated Immunity
47: CFR Part 15, subpart B, Class A (FCC)
ICES-003 Issue 4, February 2004, Class A
CNS13438 (C6357): 2006: Taiwan/BSMI: CISPR32
CNS13438 (C6357): 2006: Australia/NZ: Market Access
VCCI V-1/93.11, V-2/97.04, V-3/97, R-1216, and C-1279 Class A ITE