7. Programming
To program the keypad, you must first enter program mode by
pressing 99 # Master Code *. The default Master Code is 1234.
NOTE: If auto-entry is enabled, the*keyisnotusedtoenter
Program mode.
To change the Master Code, enter:
1 # new Master Code * new Master Code *
7.1 Programming Order
To ensure that the keypad is programmed properly in the initial
installation, program the keypad in the following order:
• Step 1: Assigning Virtual Outputs to Physical Outputs
• Step 2: Programming Output Time Durations
• Step 3: Programming Users
• Step 4: Programming Keypad Options
7.2 Assigning Virtual Outputs to Physical
Outputs
The keypad is equipped with eleven Virtual Outputs and six Physi-
cal Outputs. Virtual Outputs are functions that you can
assign to operate any Physical Output. Physical Outputs include
the main relay, the three relays on the accessory relay board, and
the two audio alerts.
• Using command 10, you can assign an y Virtual Output to
any Physical Output or disable a Physical Output.
• Each Physical Output can only have one Virtual Output
assigned to it.
IEI 212eM/242eM Standalone Installation/Programming Manual
16 Document # 6174000, Rev. 1.1