3. Keypad Tampering
To prevent tampering, a tamper switch can be installed in the sin-
gle gang box used for mounting the keypad. The tamper switch
must activate if the keypad is removed from the box and must dis-
connect power from the lock. The lock must be a fail-secure de-
vice, meaning the lock remains locked when power is removed. In
addition, once the tamper device is activated, it must be configured
so that it can only be reset from within the protected area. Only a
Sentrol 3012 or Sentrol 3025T tamper switch can be used. The dia-
grams on the next page show the suggested mounting location for
each device.
3.1 IEI Tamper Power Supplies
IEI access system power supplies are designed specifically for ac-
cess control applications. Two models are available: board level
and in a cabinet. Both feature a tamper circuit with a reset button
mounted on the circuit board. Using the tamper switch as detailed
and connected to the power supply tamper circuit, unauthorized
opening of the case or prying the unit off the wall triggers this tam-
per loop, thus preventing the lock from being released until the re-
set button is pressed.
How to Order
Access power supply with tamper circuit - in cabinet:
0291200
Access power supply with tamper circuit - board level:
0291100
IEI 212eM/242eM Standalone Installation/Programming Manual
Document # 6174000, Rev. 1.1 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IEI Technology 212eM and is the answer not in the manual?

IEI Technology 212eM Specifications

General IconGeneral
BrandIEI Technology
Model212eM
CategoryKeypad
LanguageEnglish

Related product manuals