IEI prox.pad
TM
Proximity Reader/Keypad
Access Control
Installation/Programming Manual
Document # 6055676, Rev 2.2, D4b

Table of Contents

Questions and Answers

  • E
    Elizabeth ArnoldAug 18, 2025
    How to reprogram the master code on an IEI Technology prox.pad Keypad if it's lost or the keypad won't enter program mode?
    • M
      Marc AndradeAug 18, 2025
      If your IEI Technology Keypad is not entering program mode, or you've forgotten the master code, follow these steps: 1. Turn the power to the keypad ON, then remove the main circuit board from the unit. 2. Locate the “Program” button (SW1) underneath the main circuit board and press it for about 2 seconds. Handle the board carefully, avoiding touching solder points. 3. To program a new master code, press: 1# new-code * repeat-code *. The code can be 1-6 digits. 4. To exit program mode, press *. 5. Continue programming as needed.
  • J
    Jamie WatersNov 2, 2025
    Why does the IEI Technology prox.pad red LED turn green, but the door doesn't open?
    • B
      bryanfloresNov 2, 2025
      This issue with the IEI Technology Keypad can be caused by power supply voltage problems or the locking device power supply not being set correctly. Here's how to troubleshoot: 1. Check the power supply voltage. 2. Monitor the voltage at the unit's V+ and V- terminals (on P1) with a meter. Enter a valid code and ensure that the voltage remains constant while the locking device attempts to unlock and relock. If the voltage varies by 1/4 volt or more during this test, investigate these potential causes: * Verify that the power supply is adequately rated for all powered equipment. * Verify that the locking device, if on the same power supply, is set up for the current being drawn. * Place the meter across the lock power wires at the lock to ensure the lock is receiving th...

Summary

Chapter 1: Introduction;Installation

Safety Warnings and Cautions

Installation must follow codes; static discharge precautions are essential.

Operating Modes

Description of Standalone, Wiegand, and Secured Series modes.

prox.pad Specifications

Details electrical, mechanical, and input/output specifications.

Installation Configurations

Details on Wall, Glass, and Secure installation types.

Mounting the prox.pad Unit

Guidance on selecting and performing unit mounting.

Performing a Wall Mounted Installation

Step-by-step guide for performing a wall mounted installation.

Chapter 2: Standalone Mode

Programming in Standalone Mode

Detailed programming instructions for Standalone mode.

Programming Users

Methods for adding and managing users.

Standalone Program Commands

Table of commands for Standalone mode programming.

Chapter 3: Wiegand Front End Mode

Wiegand Front End Programming

Programming instructions for Wiegand mode.

Wiegand Programming Commands

Table of commands for Wiegand mode programming.

Chapter 4: Secured Series Front End Mode

Secured Series Front End Programming

Programming instructions for Secured Series mode.

Secured Series Front End Program Commands

Table of commands for Secured Series mode programming.

Chapter 5: Troubleshooting

Troubleshooting Flow Charts

Flow charts to diagnose common issues.