prox.pad Installation/Programming Manual
2.7.4 Programming Output Relays and Audio Alerts
2.7.4.a Changing the Main Relay Time
Setting the main relay time using command 11 simultaneously sets the time for all normal access users (user type 1). The factory
default main relay time is five (5) seconds. You can set the main relay time in one-second increments from one (1) second to ninety-
nine (99) seconds using the following command sequence:
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the new main relay time (1 to 99 seconds).
Press: 11 # relay time # 0 # **
For example, to enter 10 seconds, press: 11 # 10 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
2.7.4.b Programming the Aux Relay Output Function
You can program the Aux Relay output to operate as either alarm shunt, propped door or forced door. You can also disable the relay.
In the command sequence enter the output number in output field. You can only assign a single output to the Aux Relay. Alarm shunt
is the default value so no programming is required if that's the function you want to use. The output values are listed in step 2 below.
The command sequence is as follows:
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Program the Aux Relay Output Function
Press: 15 # output # 0 # **
0 = Disabled
1 = Alarm Shunt (Default)
2 = Forced Door
3 = Propped Door
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.