prox.pad Installation/Programming Manual
2.9 Standalone Program Commands
If you need to change any of the program default values or wish to add functions, first enter program mode and then enter the desired
program command. Defaults are in bold.
Note: The master code must be changed prior to performing any programming on the prox.pad unit.
Table 8: Standalone Programming Commands
Action Desired Press Details
Enter Program Mode 99 # (Master Code)* Yellow LED blinks slowly
Change master code
1 # (new code) * (repeat code) *
Ex: 1 # 4321 * 4321 *
Code-only operation
Set main relay time 11 # tt # 0 # **
tt=1-99 seconds (default = 5
seconds)
Set AUX relay output 15 # output # 0 # **
0=disabled
1=shunt (default)
2=forced door
3=propped door
Delete Users user location # ** (See section 2.7.3)
Set/clear standard option 30 # option # s/c # ** See Chart below
Option Set Clear
0 – Audio Keypress Feedback 1 = Enabled 0 = Disabled
1 – Visual Keypress Feedback 1 = Enabled 0 = Disabled
2 – Auto Entry 0 = Disabled 1 = Enabled
3 – Operating Mode 0 = Standalone 1 = Front End
4 – Facility Code Access 0 = Disabled 1 = Enabled
5 – Forced Door Audio Alert 0 = Disabled 1 = Enabled
6 – Propped Door Audio Alert 0 = Disabled 1 = Enabled
7 – Internal REX Switch 0 = Disabled 1 = Enabled
8 – Daylight Savings Time Format 0 = US 1 = European
13 – Daylight Savings Time 0 = Disabled 1 = Enabled
14 – Prox Card Anti-Passback Select 0 = Disabled 1 = Enabled
18 – Invalid PIN Lockout Select 0 = Disabled 1 = Enabled
19 – Invalid PIN Lockout Action 0 = Timed Lockout 1 = Forced Door Output
Print User List 25 # 0 # 0 # ** (See section 2.8.2.D)
Print User List
(From Certain User Location)
25 # 0 # start user # **
Page 56 of 86 Document # 6055676, Rev 2.2, D4b