UK
SmartController CR2530
13
7 Technical data
7.1 Mechanical and electric data
Control systems
ifm electronic gmbh ● Friedrichstraße 1 ● 45128 Essen We reserve the right to make technical alterations without prior notice! 20.09.2013CR2530 / Page 1
CR2530
132
5,5
26
80
15
45°
153
LED
43
±0,5
±1
106,5
±1
Mobile controller
SmartController
16 inputs
16 outputs
2 CAN interfaces
Programming to IEC
61131-3
8...32 V DC
Technical data Controller as black box system
for the implementation of a central or decentralised system design
Mechanical data
Housing closed metal housing with ange fastening
Dimensions (H x W x D) 153 x 132 x 43 mm
Installation screw connection by means of 4 M5 x L screws to DIN 7500 or DIN 7984
mounting position horizontal or vertical to the mounting wall
Connection 1 connector 55-pole, locked, reverse polarity protection, type AMP or Framatome
contacts AMP-Junior-Timer, crimp connection 0.5/2.5 mm²
Weight 1.0 kg
Housing/storage temperature – 40...85 °C (depending on the load) / – 40...85 °C
Protection rating IP 67 (for inserted connector with individually sealed cores, e.g. EC2084)
Electrical data
Input/output channels (total) 32 (16 inputs / 16 outputs)
Inputs con gurable
digital for positive/negative sensor signals, positive with diagnostic capabilities
analogue (0...10/32 V, 0...20 mA, ratiometric)
frequency (≤ 30 kHz)
resistance measurement (16 Ω...30 kΩ)
Outputs con gurable
digital, positive switching (high side)
analogue (0.02...10 V)
PWM output (20...250 Hz), current-controlled
Operating voltage 8...32 V DC
Overvoltage ≤ 36 V for t ≤ 10 s
Undervoltage detection for U
B
≤ 7.8 V
Undervoltage shutdown for U
B
< 7.0 V
Reverse polarity protection yes
Current consumption 50 mA (at 24 V DC)
CAN interfaces 1...2
baud rate
communication pro le
CAN interface 2.0 A/B, ISO 11898
50 Kbits/s...1 Mbit/s (default 250 Kbits/s)
CANopen, CiA DS 301 V4.01, CiA DS 306 V1.3
or SAE J 1939 or free protocol
Processor Freescale PowerPC, 50 MHz