7.2 Test standards and regulations
ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice! 20.09.2013CR2530 / Page 3
CR2530 Technical data
Control systems
Test standards and regulations
CE marking EN 61000-6-2: 2005 Electromagnetic compatibility (EMC)
noise immunity
EN 61000-6-4: 2007 Electromagnetic compatibility (EMC)
radiation of interference
E1 marking UN/ECE-R10 Radiation of interference
immunity with 100 V/m
Electrical tests ISO 7637-2: 2004 Pulse 1, severity level: IV; function state C
Pulse 2a, severity level: IV; function state A
Pulse 2b, severity level: IV; function state C
Pulse 3a, severity level: IV; function state A
Pulse 3b, severity level: IV; function state A
Pulse 4, severity level: IV; function state A
Pulse 5, severity level: III; function state C
(data valid for the 24V system)
Pulse 4, severity level: III; function state C
(data valid for the 12 V system)
Climatic tests EN 60068-2-30: 2006 Damp heat, cyclic
upper temperature 55 °C, number of cycles: 6
EN 60068-2-78: 2002 Damp heat, steady state
test temperature 40 °C / 93 % RH,
test duration: 21 days
EN 60068-2-52: 1996 Salt spray test
severity level 3 (motor vehicle)
Mechanical tests ISO 16750-3: 2007 Test VII; Vibration, random
mounting location: vehicle body
EN 60068-2-6: 2008 Vibration, sinusoidal
10...500 Hz; 0.72 mm/10 g; 10 cycles/axis
ISO 16750-3: 2007 Bumps
30 g/6 ms; 24,000 shocks