liability for consequences of misuse by the operator� Improper installation and
use of the devices results in a loss of the warranty claims�
• For medium temperatures above 50 °C some parts of the housing can heat up
to over 65 °C� Moreover, during installation or in case of a fault (e�g� housing
damage) media under high pressure or hot media can leak from the system� To
avoid personal injury, take the following measures:
► Install the unit according to the applicable rules and regulations�
► Ensure that the system is free of pressure during installation�
► Protect the housing against contact with flammable substances and
unintentional contact� To do so, equip the unit with suitable protection (e�g�
protective cover)�
► Do not press the pushbuttons manually; instead use another object (e�g�
ballpoint pen)�
3 Functions and features
Pressure Equipment Directive (PED): The units comply with section 3, article 3 of
the Directive 97/23/EC and must be designed and manufactured for non-super-
heated liquids of group 2 fluids in accordance with the sound engineering practice�
The unit monitors liquid media�
It detects the 3 process categories volumetric flow, consumed quantity, medium
temperature�
Application area
• Water
• Glycol solutions
• Low viscosity oils (viscosity: 7���40 mm²/s at 40°C)
• High viscosity oils (viscosity: 30���68 mm²/s at 40°C)
Selection of the medium to be monitored → 10.5.9�