7.2.3 SIO mode in RGB mode
In this mode, fixed properties are assigned to the three digital inputs�
Input 1 - red
Input 2 - green
Input 3 - blue
By triggering the three inputs correspondingly, the user can determine the colour
of the signal lamp�
Example:
Input 1 triggered: The signal lamp glows red�
Input 3 triggered: The signal lamp glows blue�
Inputs 1 and 3 triggered: The signal lamp glows purple�
Depending on the product version, the IO-Link port is used as an input for the
buzzer of as an output for the feedback button� For the version with buzzer and
feedback button, the IO-Link parameter OUT1 (Index 580) can be used to set
whether the IO-Link port is used as input or as output�
8 Parameter setting
The unit can be configured using an IO-Link parameter setting tool (e�g�
LR
DEVICE) (→ 3.1 IO-Link)
More information is given in the IODD at www�ifm�com�