Do you have a question about the IFM Ecomat 100 CR0303 and is the answer not in the manual?
Guidance on selecting a dry, enclosed environment for mounting, avoiding torsion forces.
Instructions for securing the module using screws and washers, including torque specifications.
Ensuring sufficient heat dissipation for the device's internal electronics via the housing.
Details on AMP crimp connectors for supply, interfaces, inputs, and outputs.
Information on protecting individual electric circuits with fuses for the system and controller.
Guidelines for separate cable laying and connecting supply/ground cables via a common star point.
Recommendations for using screened cables for frequency inputs to avoid external interference.
Information on creating application software using CoDeSys and required programming system documents.
Description of the device's operating elements, status LEDs, and rotary switches.
Explanation of how rotary switches are used for configuration, e.g., baud rate and Node ID.
Details on the RGB LED status indicator and its meanings for operating states.
Detailed specifications for digital and analogue inputs, including switch-on levels and frequencies.
Detailed specifications for digital and voltage outputs, including switching voltage, current, and PWM.
List of relevant test standards and regulations for device compliance and approvals.
Guidance on selecting a dry, enclosed environment for mounting, avoiding torsion forces.
Instructions for securing the module using screws and washers, including torque specifications.
Ensuring sufficient heat dissipation for the device's internal electronics via the housing.
Details on AMP crimp connectors for supply, interfaces, inputs, and outputs.
Information on protecting individual electric circuits with fuses for the system and controller.
Guidelines for separate cable laying and connecting supply/ground cables via a common star point.
Recommendations for using screened cables for frequency inputs to avoid external interference.
Information on creating application software using CoDeSys and required programming system documents.
Description of the device's operating elements, status LEDs, and rotary switches.
Explanation of how rotary switches are used for configuration, e.g., baud rate and Node ID.
Details on the RGB LED status indicator and its meanings for operating states.
Detailed specifications for digital and analogue inputs, including switch-on levels and frequencies.
Detailed specifications for digital and voltage outputs, including switching voltage, current, and PWM.
List of relevant test standards and regulations for device compliance and approvals.
| Product type designation | CR0303 |
|---|---|
| Housing material | Plastic |
| Number of digital inputs | 8 |
| Number of digital outputs | 4 |
| Communication protocol | CAN |
| Output type | PNP |
| Storage temperature | -40...85 °C |
| Connection type | M12 connector |
| Output current | 2 A |
| Operating temperature | -25...60 °C |
| Output current per output | Max. 2 A |