Lists product models with their measuring ranges, overload, and bursting pressures.
Details 2-wire and 3-wire operation, including their respective output functionalities.
Details configuration of analogue output signals (4-20 mA or 20-4 mA) and scaling.
Covers setting two independent calibration points (CP1, CP2) and zero point calibration (COF).
Details the mechanical installation steps, including greasing, insertion, and tightening torque for the unit.
Stresses the need for qualified personnel and adherence to electrical safety standards during connection.
Details the three-step process for setting parameters: selection, value adjustment, and confirmation.
Details setting calibration points (CP1, CP2) to adjust the accuracy of the measured value curve.
Covers the unit's self-diagnostic features and how errors are reported via IO-Link and the display.
Details errors related to supply voltage and output current, with corresponding corrective actions.
Covers errors related to parameter settings, measuring range deviations, and internal sensor faults.
Covers errors related to temperature compensation, unit temperature extremes, and advice on installation.
Presents a table of default factory settings for all key parameters of the device.
Lists product models with their measuring ranges, overload, and bursting pressures.
Details 2-wire and 3-wire operation, including their respective output functionalities.
Details configuration of analogue output signals (4-20 mA or 20-4 mA) and scaling.
Covers setting two independent calibration points (CP1, CP2) and zero point calibration (COF).
Details the mechanical installation steps, including greasing, insertion, and tightening torque for the unit.
Stresses the need for qualified personnel and adherence to electrical safety standards during connection.
Details the three-step process for setting parameters: selection, value adjustment, and confirmation.
Details setting calibration points (CP1, CP2) to adjust the accuracy of the measured value curve.
Covers the unit's self-diagnostic features and how errors are reported via IO-Link and the display.
Details errors related to supply voltage and output current, with corresponding corrective actions.
Covers errors related to parameter settings, measuring range deviations, and internal sensor faults.
Covers errors related to temperature compensation, unit temperature extremes, and advice on installation.
Presents a table of default factory settings for all key parameters of the device.
| Model | PI2893 |
|---|---|
| Brand | IFM |
| Output Type | Analog |
| Connection Type | M12 Connector |
| Protection Rating | IP67 |
| Type | Pressure Sensor |
| Operating Voltage | 18-30 V DC |
| Material | Stainless Steel |
| Housing Material | Stainless Steel |