Operating instructions
Electronic pressure sensor
PI28xx
80260760/ 00 03 / 2019
UK
Question and Answer IconNeed help?

Do you have a question about the IFM PI2893 and is the answer not in the manual?

Summary

Safety Instructions

Functions and Features

Applications and Specifications

Lists product models with their measuring ranges, overload, and bursting pressures.

Device Functionality

Operating Modes

Details 2-wire and 3-wire operation, including their respective output functionalities.

Analogue Function Configuration

Output Signal Configuration (4-20 mA;20-4 mA)

Details configuration of analogue output signals (4-20 mA or 20-4 mA) and scaling.

Customer-Specific Calibration

Calibration Points and Zero Point Adjustment

Covers setting two independent calibration points (CP1, CP2) and zero point calibration (COF).

Installation Procedures

Process Connection and Mounting

Details the mechanical installation steps, including greasing, insertion, and tightening torque for the unit.

Electrical Connection Guidelines

Safety and Connection Requirements

Stresses the need for qualified personnel and adherence to electrical safety standards during connection.

2-Wire Connection Details

3-Wire Connection Details

Main Menu Structure

Main Menu Parameter Explanations

Level 2 Menu Structure

Level 2 Menu Parameter Explanations

Level 3 Menu Structure (Simulation)

Level 3 Menu Parameter Explanations

Parameter Setting Procedures

General Parameter Setting Steps

Details the three-step process for setting parameters: selection, value adjustment, and confirmation.

Parameter Locking and Unlocking

Output Signal Configuration

Setting Switching Limits

Analogue Value Scaling

User Specific Settings

Calibrating Measured Value Curve

Measured Value Curve Calibration

Details setting calibration points (CP1, CP2) to adjust the accuracy of the measured value curve.

Service Functions

Simulation Function Access

Setting Simulation Values

Simulation Time and Start

Self-Diagnosis and Error Indication

Error Detection and Indication

Covers the unit's self-diagnostic features and how errors are reported via IO-Link and the display.

Error Codes and Corrective Measures

Supply Voltage and Output Current Errors

Details errors related to supply voltage and output current, with corresponding corrective actions.

Parameter and Internal Sensor Errors

Covers errors related to parameter settings, measuring range deviations, and internal sensor faults.

Locked Settings and Analogue Output Errors

Temperature and Unit Specification Errors

Covers errors related to temperature compensation, unit temperature extremes, and advice on installation.

Setting Ranges for Parameters

Factory Default Settings

Default Parameter Values Overview

Presents a table of default factory settings for all key parameters of the device.

Summary

Safety Instructions

Functions and Features

Applications and Specifications

Lists product models with their measuring ranges, overload, and bursting pressures.

Device Functionality

Operating Modes

Details 2-wire and 3-wire operation, including their respective output functionalities.

Analogue Function Configuration

Output Signal Configuration (4-20 mA;20-4 mA)

Details configuration of analogue output signals (4-20 mA or 20-4 mA) and scaling.

Customer-Specific Calibration

Calibration Points and Zero Point Adjustment

Covers setting two independent calibration points (CP1, CP2) and zero point calibration (COF).

Installation Procedures

Process Connection and Mounting

Details the mechanical installation steps, including greasing, insertion, and tightening torque for the unit.

Electrical Connection Guidelines

Safety and Connection Requirements

Stresses the need for qualified personnel and adherence to electrical safety standards during connection.

2-Wire Connection Details

3-Wire Connection Details

Main Menu Structure

Main Menu Parameter Explanations

Level 2 Menu Structure

Level 2 Menu Parameter Explanations

Level 3 Menu Structure (Simulation)

Level 3 Menu Parameter Explanations

Parameter Setting Procedures

General Parameter Setting Steps

Details the three-step process for setting parameters: selection, value adjustment, and confirmation.

Parameter Locking and Unlocking

Output Signal Configuration

Setting Switching Limits

Analogue Value Scaling

User Specific Settings

Calibrating Measured Value Curve

Measured Value Curve Calibration

Details setting calibration points (CP1, CP2) to adjust the accuracy of the measured value curve.

Service Functions

Simulation Function Access

Setting Simulation Values

Simulation Time and Start

Self-Diagnosis and Error Indication

Error Detection and Indication

Covers the unit's self-diagnostic features and how errors are reported via IO-Link and the display.

Error Codes and Corrective Measures

Supply Voltage and Output Current Errors

Details errors related to supply voltage and output current, with corresponding corrective actions.

Parameter and Internal Sensor Errors

Covers errors related to parameter settings, measuring range deviations, and internal sensor faults.

Locked Settings and Analogue Output Errors

Temperature and Unit Specification Errors

Covers errors related to temperature compensation, unit temperature extremes, and advice on installation.

Setting Ranges for Parameters

Factory Default Settings

Default Parameter Values Overview

Presents a table of default factory settings for all key parameters of the device.

IFM PI2893 Specifications

General IconGeneral
ModelPI2893
BrandIFM
Output TypeAnalog
Connection TypeM12 Connector
Protection RatingIP67
TypePressure Sensor
Operating Voltage18-30 V DC
MaterialStainless Steel
Housing MaterialStainless Steel

Related product manuals