EasyManua.ls Logo

IFM PI2799 User Manual

IFM PI2799
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating instructions
Electronic pressure sensor
PI27xx
704924/00 01/2011
UK

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the IFM PI2799 and is the answer not in the manual?

IFM PI2799 Specifications

General IconGeneral
TypePressure sensor
Switching distancenot applicable
Connection typeM12 connector
Protection classIP67
Process connectionG 1/4
MaterialsStainless steel
Housing materialStainless steel

Summary

Safety Instructions

General Safety Precautions

Provides crucial safety information and precautions for installation and use of the sensor.

Sensor Functionality

Switching Output Functionality

Describes hysteresis and window functions for configuring switching outputs.

Analogue Output Functionality

Explains how the analogue output signal can be configured and scaled.

Customer-Specific Calibration

Calibrating the Measured Value Curve

Guides users through calibrating the sensor's measured value curve for accuracy.

Electrical Connection

2-Wire Operation Connection

Provides the wiring diagram and procedure for connecting the sensor in 2-wire mode.

IO-Link Connection

Details the wiring requirements for IO-Link parameter setting and communication.

3-Wire Operation Connection

Shows wiring diagrams for various 3-wire operation configurations, including switching and analogue outputs.

Menu System Navigation

Main Menu Parameter Explanation

Provides detailed explanations for each parameter found in the main menu.

Extended Functions Menu (Level 2)

Level 2 Parameter Explanation

Offers comprehensive explanations for all parameters within the level 2 menu.

Simulation Menu (Level 3)

Level 3 Simulation Parameter Explanation

Details the parameters and settings available for simulation mode.

Parameter Setting Procedures

General Parameter Setting Steps

Outlines the three essential steps for setting any parameter on the device.

Locking and Unlocking Settings

Describes the procedure for electronically locking and unlocking parameter settings.

Output Signal Configuration

Setting Output Functions

How to configure switching functions (hysteresis, window) for OUT1 and OUT2.

User-Specific Settings

Signal Damping and Calibration

Service Functions

Resetting Parameters to Factory Defaults

Procedure for restoring all device parameters to their original factory settings.

Simulation Functions

Simulation Function Details

Unit Operation and Diagnostics

Technical Specifications

Factory Default Settings

Related product manuals