DataLink Technologies Gateways, Inc.
Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390
8
Note: The new parameters will be written to memory upon returning to the main
menu by pressing 4 ENTER↵
↵↵
↵.
2) Modify Password
The login password can be modified with main menu option 2.
Enter Selection: 2
Enter old password: ******
Enter new password: ******
Renter new password: ******
New password accepted
3) View / Modify Online Parameters
To edit the Online Parameters for DH+ port and serial port, from the main menu, press
“3” followed by ENTER↵. The following submenu is displayed.
Enter Selection: 3
Online Parameters:
1.) Node Address Oct:1o, Hex:0x01, Dec:1
2.) DH+ Baud Rate 57.6 KBaud
3.) Serial Parameters
4.) DF1 Parameters
5.) Save Parameters and Exit
6.) Return to Main Menu
Enter Selection:
To edit the DH+ node address, press “1” ENTER↵, enter the two-digit octal value and
press ENTER↵..
Enter Selection: 1