OPERATING AND PROGRAMMING INSTRUCTIONS
4-4
The configuration of the controller is as follows.
- Press Up, Down, and then the program will ask for a password (password is 9999)
to the C0 – C10, then press the Enter button to settings the controller.
- PaSS: (change the password) can change the password.
-
tFtr: (setting Forward / Reveres) can be set at the turn of the basket is a Forward
/ Reverse.
- trot: (set the rotation of the basket) can be set from 3 – 90 seconds.
- tstP: (set time to stop rotation of the basket) can be set to stop the rotation of
the basket from 0-60 seconds.
- Anti: (set to anti crease) can be set to anti crease.
- trEF: (the reference temperature) is the temperature. Has the same value as the
program runs.
- buZZ: (warning time) can set the alarm time from 0-99 seconds, but if it is set to
0, the alarm always.
- AtEd: (the end of operation setting) can be set to working by the end of which
the time or the temperature is set to 0, it will be the end of the working of time.
If set to 1 to 99 to the end of the working the temperature.
- dtP1: (the actual temperature at the time) while present temperature setting
MESSAGE CAUSE
door
- Door is not closed all the way.
- Door switch out of proper adjustment.
- Failed door switch.
- Broken connection / wire in main door circuit.
- Failed 24 VAC transformers.
AH
- Temperature is over than 110 °C
tSFL
- Temperature is lower than 20 °C
OL
- Drive motor is over current or has failed.
- Blower motor is over current or has failed.
dP
- Sail switch (rear the machine) is out of adjustment or has
failed.
- Failed direction of blower or blower is not operation.
- Filter (lint drawer) is not clean.
E. MEANING OF THE ALARM MASSAGE
D. SETTING THE CONTROLLE
R