3.25 COMBUSTION PARAMETERS.
3.26 TECHNICAL DATA.
- The maximum sound level emitted during
boiler operation is < 55dBA. e sound level
value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with
extension of ue gas exhaust system according
to product standards.
NG (G20) LPG (G31)
Gas nozzle diameter mm 8,4 6,5
Supply pressure kPa 1,13 2,75
Flue ow rate at nominal heat output kg/h 81 82
Flue ow rate at min heat output kg/h 9 9
CO
2
at Q. Nom./Min. % 9,40 / 9,10 10,60 / 10,10
CO / CO
2
at Nom./Min. Q. Nom./Min. - 0,00157 / 0,00001 0,00184/ 0,00001
NO
X
at 0% of O
2
at Q. Nom./Min. mg/kWh 43 / 17 43 / 21
Flue temperature at nominal output °C 52 53
Flue temperature at minimum output °C 48 48
Nominal heat input kW (MJ/h) 51,3 (204,9)
Minimum heat input kW (MJ/h) 5,5 (21,9)
Nominal heat output (useful) kW 49,9
Minimum heat output (useful) kW 5,0
* Eciency 80/60 Nom./Min. % 97,3 / 91,2
* Eciency 50/30 Nom./Min. % 106,8 / 99,7
* Eciency 40/30 Nom./Min. % 107,4 / 103,5
Heat loss at casing with burner O/On (80-60°C) % 0,30 / 0,90
Heat loss at ue with burner O/On (80-60°C) % 0,03 / 1,80
Central heating circuit max. operating pressure kPa 440
Central heating circuit max. operating temperature °C 90
Adjustable central heating temperature °C 20 - 85
Head available with 1000 l/h ow rate kPa (m H
2
O) 60,10 (6,13)
Weight of full boiler kg 54,2
Weight of empty boiler kg 51,4
Boiler water content l 2,8
Electrical connection V/Hz 230/50
Nominal absorption A 1,0
Installed electric output W 155
Pump consumption W 57
EEI value - ≤ 0,23 - Part. 3
Fan power consumption W 79
Equipment electrical system protection - IPX5D
Functioning room max. temperature °C +50
Functioning room min. temperature °C -5
Functioning room min. temperature with anti-freeze kit (Optional) °C -15
Flue gas max. temperature °C 75
NO
X
class - 5
Weighted NO
X
mg/kWh 39
Weighted CO mg/kWh 15
Type of appliance C13 / C33 / C63 / B23p / B33 / B53p
Combustion parameters: measuring conditions
of useful eciency (ow temperature/return
temperature= 80/60 °C), ambient temperature
reference = 15°C.
- (*) Eciencies refer to the lower heating value.