28 VICTRIX PRO V2 35 EU COMBUSTION FEATURES
Gas ow rates refer to net caloric value at a temperature of 15°C and at a pressure of 1013 mbar.
Flue gas temperature values refer to an air inlet temperature of 15°C and ow/return temperature of 80/60°C.
Methane (G20) LPG (G31)
Maximum heat input of gas G20 m
3
/h 3.69
Min. heat input of gas G20 m
3
/h 0.41
Maximum heat input of gas G31 kg/h 2.71
Min. heat input of gas G31 kg/h 0.30
Supply pressure mbar 20 37
Flue ow rate at maximum nominal heat output kg/h 54 56
Flue ow rate at maximum nominal heat output
gas 20% H2NG
kg/h 57
Flue ow rate at min heat output kg/h 6 6
Flue ow rate at min heat output
gas 20% H2NG
kg/h 7
Chimney losses with burner on (100% Pn) (80/60°C) % (W) 2,7 (937)
Chimney losses with burner o % (W) 0,03 (10)
Casing losses with burner on (100% Pn) (80/60°C) % (W) 0,31 (110)
Casing losses with burner o % (W) 0,32 (111)
Flue gas temperature Maximum Heat Input °C 79 83
Flue gas temperature Min. Heat Input °C 60 62
CO
2
at Maximum Heat Input % 9.6 10.6
CO
2
at Maximum Heat Input
gas 20% H2NG
% 8.4
CO
2
at Min. Heat Input % 9.1 10.5
CO
2
at Min. Heat Input
gas 20% H2NG
% 8.1
CO at Maximum Heat Input ppm 240 280
CO at Maximum Heat Input
gas 20% H2NG
ppm 110
CO at Min. Heat Input ppm 3 2
CO at Min. Heat Input
gas 20% H2NG
ppm 1
Weighted CO mg/kWh 27 32
NO
x
at the Maximum Heat Input mg/kWh 60 68
NO
x
at Min. Heat Input mg/kWh 24 42
Weighted NO
x
mg/kWh 37 40
NO
x
class - 6 6