VICTRIX PRO V2 EU
127
e remote control allows to manage, control and program
operation of the generator it is connected to. It can be set and
programmed via parameters that allow to guarantee ideal
temperature conditions at all times of the day and night for
each individual day of the week, both for the C.H. system
and the D.H.W. system (VICTRIX PRO V2 EU coupled to
a storage tank unit). e remote control enables the user to
keep under control and within reach all the important infor-
mation regarding operation of the appliance and the heating
system with the ability to easily act on settings with no need
to go to where the generator is physically present. e climate
chrono-thermostat incorporated into the Remote control en-
ables the system ow temperature to be adjusted to the actual
needs of the room being heated, in order to obtain the desired
room temperature with extreme precision and therefore with
evident saving in running costs.
e Remote control connects to the boiler via a "Clip-in"
communication board and 2 BUS data cables, from which it
is powered.
e ADVANCED TEMPERATURE CONTROL device be-
longs to Class V* or VI.
It allows you to increase the seasonal energy eciency value
by 3%* or 4%
It is connected to the boiler by a Clip-in communication
board, code: 3.034122 and 2 BUS cables of a maximum length
of 50 metres.
Once the Remote control and communication board are
connected, remove the jumper "X40" present as per standard
on the boiler board.
With Remote control installation it is also advisable to install
an external probe.
e device allows you to:
manage a maximum of one zone;
set two room temperature values, one for day (comfort
temperature) and one for night (reduced temperature);
manage the temperature of the DHW (with a storage tank
unit managed as zone or using a 3-way valve);
select the functioning mode for CH and DHW for each
individual hydraulic circuit:
- comfort temperature functioning,
- reduced temperature functioning,
- adjustable anti-freeze temperature functioning;
manage the boiler ow temperature depending on the ex-
ternal temperature and the room temperature with setting
of the climatic curve;
obtain information regarding the system:
- system temperature,
- operating mode,
- counter data,
- timer program,
- pump operation status;
set the operation parameters:
- functioning times,
- system mode,
- DHW,
- direct circuit,
- date and time;
display, via self-diagnosis system, of any functioning anom-
alies with error codes;
show the date, time, day of the week and the boiler temper-
ature on the display.
29 HIGH POWER REMOTE CONTROL FOR SINGLE BOILER CODE 3.020358
29.1 FEATURES
Dimensions (H x L x P) mm 138 x 90 x 28