EasyManua.ls Logo

Imperx Cheetah C2020 - Page 17

Imperx Cheetah C2020
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cheetah Pregius Camera with Camera Link – User Manual
July 6, 2018 Page 17 of 64 Rev 1.1
Figure 6: OUT1 LVTTL electrical connection.
D. Output OUT 2 – Solid state relay, optically isolated
Output OUT2 is an optically isolated switch. There is no pull-up voltage on either contact.
External pull-up voltage of up to 25 volts is required for operation. Output is not polarity
sensitive. AC or DC loads are possible. The voltage across OUT2 Contact 1 and OUT2
Contact 2 must not exceed 25 volts and the current through the switch must not exceed
50 mA. On resistance is less than 5 Ohms.
Figure 7: Open drain logic driver.
Figure 8: Low side load driver.