25
3.2 PUMPMEDIUM
Pumpmediumcanbepurewateroramixtureofpurewaterandglycol,whichisappropriateforcentralheating
system.WatermustmeetwaterqualitystandardVDI2035.Themediummustbefreefromaggressiveorexplosive
additives,freefrommixturesofmineraloilsandsolidorfibrousparticles.Thepumpshouldnotbeusedforpumping
flammable,explosivemediaandinanexplosiveatmosphere.
3.3 TEMPERATURESANDAMBIENTHUMIDITY
3.4 ELECTRICALSPECIFICATIONS
3.4.1 CURRENT,VOLTAGEANDPOWERRATINGS
Permitted ambient and media temperature:
Ambient temperature
[°C]
Medium temperature [°C]
Relative ambient humidity
min. max.
Upto25 ‐10 110
<95%
30 ‐10 100
35
‐10 90
40 ‐10 80
Operationoutsiderecommendedconditionsmayshortenpumplifetimeandvoidthewarranty.
Electrical ratings
Pump Rated voltage
Rated power
[W]
Rated current
[A]
Rated
current
(I
max
) [A]
Startup
NMT(D)MAX(C)32‐120
230VAC±15%,
47‐63Hz
Pumpscanoperate
atreducedvoltage
withlimitedpower
(P=I
max
*U)
370 1.8 4.3
Build‐in
startup
circuit
NMT(D)MAX(C)40‐40 110 1 4.3
NMT(D)MAX(C)40‐80 270 1.3 4.3
NMT(D)MAX(C)40‐120 480 2.3 4.3
NMT(D)MAX(C)40‐180 680 3.4 4.3
NMT(D)MAX(C)50‐40 160 1.3 4.3
NMT(D)MAX(C)50‐80 370 1.7 4.3
NMT(D)MAX(C)50‐120 560 2.5 4.3
NMT(D)MAX(C)50‐120 830 3.6 4.3
NMT(D)MAX(C)65‐40 230 1.1 4.3
NMT(D)MAX(C)65‐80 560 2.6 4.3
NMT(D)MAX(C)65‐120 810 3.5 4.3
NMT(D)MAX(C)80‐40 390 1.8 4.3
NMT(D)MAX(C)80‐40 390 1.8 4.3
NMT(D)MAX(C)80‐80 800 3.5 4.3
NMT(D)MAX(C)80‐80 800 3.5 4.3