EasyManua.ls Logo

IMPPUMPS NMT MAX Series - Pump Medium; Temperatures and Ambient Humidity; Electrical Specifications

IMPPUMPS NMT MAX Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
3.2 PUMPMEDIUM
Pumpmediumcanbepurewateroramixtureofpurewaterandglycol,whichisappropriateforcentralheating
system.WatermustmeetwaterqualitystandardVDI2035.Themediummustbefreefromaggressiveorexplosive
additives,freefrommixturesofmineraloilsandsolidorfibrousparticles.Thepumpshouldnotbeusedforpumping
flammable,explosivemediaandinanexplosiveatmosphere.
3.3 TEMPERATURESANDAMBIENTHUMIDITY
3.4 ELECTRICALSPECIFICATIONS
3.4.1 CURRENT,VOLTAGEANDPOWERRATINGS
Permitted ambient and media temperature:
Ambient temperature
[°C]
Medium temperature [°C]
Relative ambient humidity
min. max.
Upto25 ‐10 110
<95%
30 ‐10 100
35
‐10 90
40 ‐10 80
Operationoutsiderecommendedconditionsmayshortenpumplifetimeandvoidthewarranty.
Electrical ratings
Pump Rated voltage
Rated power
[W]
Rated current
[A]
Rated
current
(I
max
) [A]
Startup
NMT(D)MAX(C)32120
230VAC±15%,
47‐63Hz
Pumpscanoperate
atreducedvoltage
withlimitedpower
(P=I
max
*U)
370 1.8 4.3
Build‐in
startup
circuit
NMT(D)MAX(C)40‐40 110 1 4.3
NMT(D)MAX(C)40‐80 270 1.3 4.3
NMT(D)MAX(C)40‐120 480 2.3 4.3
NMT(D)MAX(C)40‐180 680 3.4 4.3
NMT(D)MAX(C)50‐40 160 1.3 4.3
NMT(D)MAX(C)50‐80 370 1.7 4.3
NMT(D)MAX(C)50‐120 560 2.5 4.3
NMT(D)MAX(C)50‐120 830 3.6 4.3
NMT(D)MAX(C)65‐40 230 1.1 4.3
NMT(D)MAX(C)65‐80 560 2.6 4.3
NMT(D)MAX(C)65‐120 810 3.5 4.3
NMT(D)MAX(C)80‐40 390 1.8 4.3
NMT(D)MAX(C)80‐40 390 1.8 4.3
NMT(D)MAX(C)80‐80 800 3.5 4.3
NMT(D)MAX(C)80‐80 800 3.5 4.3

Table of Contents