38
6 ERROR AND TROUBLESHOOTING
Ifpumpfailureoccurs,theerrorcausingthefailurewillappearinthedisplayscreen.
Errorsonthescreenareidentifiedas:
EXY
E Errormarking
X Errorgroup
YServicecode
Error group
(X)
Error description Possible cause and solution
1 Lowloaddetected Thereisnomediuminthepump.Checkifthereismediuminthesystem.
2 Motoroverload
Excessivecurrentloadorblockedrotor.Iftheissuepersists,checkifthe
rotorisspinningfreely.
3 Motortoohot
Motorhasexceededallowedtemperatureandisnowstoppedtocool
down.Oncecooled,itwillautomaticallyrestart.
4 Electronicserror
Anelectronicserrorwasdetected.Thepumpcanstilloperate,butneeds
servicing.
5 Motor/statorfailure Therecouldbeaninterruptioninthemotorwinding.Pumpneedsservicing.
Theservice code (Y)isintendedforservicepersonal.
Ifthepumpisunresponsive,disconnectandconnectitbacktotheelectricalgrid.
7 FAULT FINDING
7.1 ERRORCODES
ThefollowingcodeswillshowupondisplaypanelandontheappropriateModbusregisterstohelpyoudiagnose
thecauseofimproperoperation.