MODEL NUMBER: ISC920-0-0-GB-XX
ISC921-5-0-GB-XX
ImproX IXP20 Controller
INSTALLATION MANUAL
SPECIFICATIONS
Working Environment
Plastic Housing ............................
Designed to work in an indoor (dry)
environment similar to IP40. The Controller is
not sealed against water.
Input Voltage ................................
10 V DC to 30 V DC, polarity sensitive.
Power Requirements (ISC920)
12 V DC with no peripherals
connected and relays off ........
24 V DC with no peripherals
connected and relays off ........
Power Requirements (ISC921)
12 V DC with no peripherals
connected and relays off ........
24 V DC with no peripherals
connected and relays off ........
Relay Power Requirements ........
An additional ~0.4 W per Relay in use.
Real Time Clock (RTC) Backup
Battery
Battery Type ...........................
1 x 3 V, CR2032, Lithium cell Battery.
Battery Life .............................
1 year with power OFF,
5 years with Power ON,
5 years Storage with Battery Tab in place.
Ethernet Port ................................
Standard Ethernet RJ45 connector.
10/100 Base T, half or full duplex.