Chapter 4 Maintenance & Repair 49
c When flat spots on the outer wires appear and those outside wires are less than 2/3 the
thickness of the unworn outer wire.
d When there is a decrease of diameter indicating a core failure.
e When kinking, crushing, birdcaging or other distortion occurs.
f When there is noticeable heat damage (discoloration) of the rope by any means.
g When the diameter is reduced from nominal size by 1/32" (0.8 mm) or more.
NOMINAL
SIZE - 1/32"
(0.8 mm)
NOMINAL
SIZE
h If a broken wire protrudes or loops out from the core of the rope.