EasyManua.ls Logo

Infineon TLE5501 Series - Page 17

Infineon TLE5501 Series
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s Manual 17 Rev. 1.0
2019-04-29
TLE5501
TMR-Based Angle Sensor
Calibration
Figure 16 Typical angle error with initial calibration at 25°C/50mT and subsequent measurements
considering 10% magnetic field change due to aging and air gap variation (i.e. 45mT @25°C).
Magnetic field values change with a TC of -2000ppm/K (ferrite magnet material). Magnetic
field values are indicated at each measurement temperature.
0.1
0.15
0.2
0.25
0.3
0.35
-50 -25 0 25 50 75 100 125 150 175
angle error (°)
temperature (
°
C)
50mT
Initial calibration
50.8mT
49.1mT
47.2mT
45.0mT
42.8mT
39.6mT
36.0mT
33.8mT