What to do if my Ingersoll-Rand Air Compressor shuts down?
- MMr. James ZunigaAug 9, 2025
If your Ingersoll-Rand Air Compressor shuts down, ensure the installation area has adequate ventilation and the cooling fan is operating. If not, reset the circuit breaker inside the starter box. Check and add coolant if required. Clean dirty cooler cores. Also, inspect for a restricted or malfunctioning blowdown valve or minimum pressure check valve, and check for air leaks from the tank or blowdown piping. Adjust sump pressure, check for defective sensor, bad sensor connection, or broken sensor wires. Try interchanging any two line connections (L1, L2, L3) at the starter. Check for loose wires and the supply voltage. Verify the heater size and inspect starter contactors.