Why my Ingersoll-Rand Man Rider LS2-150RLP-L E will not operate?
- EevanmorenoAug 16, 2025
If your Ingersoll-Rand winch is not operating, start by checking the air supply line connections and hoses to ensure sufficient air supply. If the winch is overloaded, reduce the load to stay within the rated capacity. Also, verify that the emergency stop valve is not engaged and reset it if necessary. Check hose and fitting connections for air leaks, inspect hoses for breaks, and tighten fittings or replace hoses as needed. Install or drain air system moisture traps, moisture collecting air receivers and compressor aftercoolers to prevent air lines from freezing due to water in the air supply. After that, disconnect lines at the winch inlet and purge with clean, dry air or nitrogen.