SmartLine
Conventional fire detection control panel
Extinguishant system control panel
Alarm transmission and fault warning routing
equipment with integrated power supply equipment
Installation and programming manual
EN 54-2
EN 54-4
EN 54-21
EN 12094-1
0051
0051-CPR-1412
0051-CPR-1413
0051-CPR-1414

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INIM Electronics SmartLine020-2 and is the answer not in the manual?

INIM Electronics SmartLine020-2 Specifications

General IconGeneral
Partitions4
Operating Temperature-10°C to +55°C
Storage Temperature-20°C to +60°C
Humidity95% non-condensing
Protection RatingIP30
Communication InterfaceRS485

Summary

SmartLine Fire Alarm Panel Overview

Installation Instructions for SmartLine System

Connecting Detection Lines and I/O

Details wiring procedures for detection lines, generic contacts, and I/O lines.

Dialler and RS485 BUS Connections

Explains connecting alarm diallers, fault communications, and RS485 BUS devices.

Signal Outputs and Extinguishant Module

Covers connecting fault, alarm, NAC, AUX, RELAY outputs, and the extinguishant module.

Power Supply and Battery Installation

Details connecting mains power, batteries, and the thermal probe for system operation.

System Power-Up and Configuration

Wiring Integrity Testing

Provides a detailed checklist for verifying wiring before powering up the system.

System Power-Up Sequence

Guides through the system power-up sequence, including LED status and reset procedures.

Introduction to Panel Programming

Programming from the Control Panel

Zone and Line Parameter Programming

Details programming zone parameters, detection line types, and I/O line configurations.

Output Programming

Introduces programming options for outputs like RELAY and NAC.

Detection Line Threshold Adjustment

Guided Threshold Settings Procedure

Explains the wizard-based procedure for configuring detection line thresholds.

Programming the Extinguishant Board

Extinguishant Board Operating Principles

Illustrates the logic flow for automatic and manual activation of the extinguishant system.

Configuring RS485 BUS Devices

SmartLeague Software Operations

System Maintenance Procedures

Routine Maintenance and Event Viewing

Lists routine tasks like cleaning, LED tests, event log viewing, and day/night mode management.

Diagnostics and Fault Solutions

Terminal Fault Detection ('Open'/'Shorted')

Explains how to diagnose and resolve 'Open' and 'Shorted' faults on terminals.

Repeater and Battery Fault Troubleshooting

Provides steps to troubleshoot issues with repeaters and battery faults.

Other Faults and System Messages

Lists common fault messages like Dialler Fault, Mains Fail, and Maintenance expiry.