22
‘STANDBY’. A ‘PENDING’ operating status of the first SD indicates the
unit is busy with another operation. In this case, cancel the ongoing
operation by entering the ‘AT+BTCANCEL command.
2. Search other local Bluetooth devices by entering the ‘AT+BTINQ?’ command.
3. Check the search list. Enter ‘ATD’ command in the BD_ADDR of any
Bluetooth device for connection. During the connection process, the
STATUS LED will flash green every second.
4. Connection is indicated by the SD returning a ‘CONNECT’ message and
displaying a green STATUS LED.
ATD000B53000080
OK
CONNECT
AT+BTINQ?
000B53000080,PSDv2g-000080,001F00
0004B300E205,AP2002:1 #0,020300
OK
AT+BTINFO?
000B530000A9,PSDv2g-0000A9,MODE0,STANDBY,0,0
OK