MD280 User Manual Description of Function Codes
- 119 -
Value Function Description
5
Upper limit
frequency reached
When the set frequency and running frequency are equal
to or larger than the upper limit frequency, the terminal
becomes ON.
6
Lower limit
frequency reached
When the set frequency and running frequency are lower
than or equal to the lower limit frequency, the terminal
becomes ON.
7
Zero-speed running
QRRXWSXWDWVWRS
If the AC drive runs with the output frequency of zero or
stops, the terminal becomes ON.
8
Motor overload pre-
warning
7KH$&GULYHMXGJHVZKHWKHUWKHPRWRUORDGH[FHHGVWKH
overload pre-warning threshold before performing the
SURWHFWLRQDFWLRQ,IWKHSUHZDUQLQJWKUHVKROGLVH[FHHGHG
the terminal becomes ON. For motor overload parameters,
see the descriptions of FB-00 to FB-02.
9
AC drive overload
pre-warning
The terminal becomes ON before the AC drive overload
protection action is performed.
10
Set count value
reached
The terminal becomes ON when the count value reaches the
value set in F7-08.
11
Designated count
value reached
The terminal becomes ON when the count value reaches the
value set in F7-09.
12 Length reached
The terminal becomes ON when the detected actual length
H[FHHGVWKHYDOXHVHWLQ)
13 PLC cycle complete
When simple PLC completes one cycle, the terminal outputs
a pulse signal with width of 250 ms.
14
Accumulative
running time
reached
,IWKHDFFXPXODWLYHUXQQLQJWLPH)RIWKH$&GULYH
H[FHHGVWKHWLPHVHWLQ)WKHWHUPLQDOEHFRPHV21
15
Communication
setting
Refer to the communication protocol.
16 Ready for run
When there is no fault, the bus voltage is normal, the
terminal with the function of coast to stop is disabled, and the
AC drive can be running, the terminal becomes ON.
17 AI1 > AI2
When the absolute value of AI1 setting is larger than that of
AI2, the terminal becomes ON.
18
Detecting zero
current
When the AC drive detects zero current, the terminal
becomes ON.
19
([WHUQDOEUDNLQJ
signal
See the descriptions of F5-39 and F5-40.
20
Software
overcurrent
See the description of F5-27.
21 Fault output 2
:KHQDIDXOWLQFOXGLQJWKHXQGHUYROWDJHIDXOWRFFXUVRQWKH
AC drive, the terminal becomes ON.
22
Zero-speed running
2
,IWKH$&GULYHUXQVZLWKWKHRXWSXWIUHTXHQF\RIH[FHSW
WKHVWRSVWDWHWKHWHUPLQDOEHFRPHV21