21
F0-07 V/F curve selection
0: line V/F curve
1: Reserved
2: square V/F curve
1 0 × 7
F0-08
V/F control torque
boost
0.0: (automatic)
0.1% ~ 30.0%
0.1% 3.5% 8
F0-09
Dl1 terminal function
selection
1 1 × 9
F0-10
DI2 terminal function
selection
1 4 × 10
F0-11
DI3 terminal function
selection
1 12 × 11
F0-12
DI4 terminal function
selection
0: No function
1: Forward running (FWD)
2: Reverse running (REV)
3: 3-line control mode
4: Forward jog (FJOG)
5: Reverse jog (RJOG)
6: Terminal UP
7: Terminal DOWN
8: Coast to stop
9: Fault reset (RESET)
10: Reserved
11: External fault input
12: Multi-speed terminal 1
13: Multi-speed terminal 2
14: Reserved
15: Acceleration and deceleration time
selection
16: frequency reference switching
between panel potentiometer and AI
17to 18: Reserved
19: UP/DOWN setting clearance (terminal
and keypad)
20: Running command switching terminal
(between panel control and terminal)
21: Reserved
(When selecting PULSE, any function of
Dl4 is invalid and can only correspond to
PULSE input.)
1 13 × 12
F0-13 DO output selection
0: No output
1: Inverter is running
2: Fault output
3: Preset frequency arrived
1 1 13
F0-14 AO output selection
0: Running frequency
1: Setting frequency
2: Output current
3: PULSE input (corresponding to
reference)
4: Panel potentiometer (corresponding to
reference)
5: AI (corresponding to reference)
1 0 14