Description of Function Codes
MD380 User Manual
- 218 -
Function Code Parameter Name Setting Range Default
FC-34 Running time of simple PLC reference 8 0.0–6553.5s (h) 0.0s (h)
FC-35
Acceleration/deceleration time of simple
PLC reference 8
0–3 0
FC-36 Running time of simple PLC reference 9 0.0–6553.5s (h) 0.0s (h)
FC-37
Acceleration/deceleration time of simple
PLC reference 9
0–3 0
FC-38 Running time of simple PLC reference 10 0.0–6553.5s (h) 0.0s (h)
FC-39
Acceleration/deceleration time of simple
PLC reference 10
0–3 0
FC-40 Running time of simple PLC reference 11 0.0–6553.5s (h) 0.0s (h)
FC-41
Acceleration/deceleration time of simple
PLC reference 11
0–3 0
FC-42 Running time of simple PLC reference 12 0.0–6553.5s (h) 0.0s (h)
FC-43
Acceleration/deceleration time of simple
PLC reference 12
0–3 0
FC-44 Running time of simple PLC reference 13 0.0–6553.5s (h) 0.0s (h)
FC-45
Acceleration/deceleration time of simple
PLC reference 13
0–3 0
FC-46 Running time of simple PLC reference 14 0.0–6553.5s (h) 0.0s (h)
FC-47
Acceleration/deceleration time of simple
PLC reference 14
0–3 0
FC-48 Running time of simple PLC reference 15 0.0–6553.5s (h) 0.0s (h)
FC-49
Acceleration/deceleration time of simple
PLC reference 15
0–3 0
FC-50 Time unit of simple PLC running
0: s (second)
1: h (hour)
0
Function Code Parameter Name Setting Range Default
FC-51 Reference 0 source
0: Set by FC-00
1: AI1
2: AI2
3: AI3
4: Pulse setting
5: PID
6: Set by preset frequency (F0-08),
modied via terminal UP/DOWN
0
It determines the setting channel of reference 0. You can perform convenient switchover
between the setting channels. When multi-reference or simple PLC is used as frequency
source, the switchover between two frequency sources can be realized easily.