Loading...
Product Information MD380 User Manual
- 20 -
The housing types of the MD380 models with different voltage and power classes are listed
in the following table.
Table 2-1 Housing types for different voltage and power classes
Voltage & Power Class Housing Type
Three-phase 220 V
0.4–2.2 kW Plastic housing
Three-phase 220 V
0.4–7.5 kW Plastic housing
11–75 kW Sheet metal housing
Three-phase 380 V
0.75–15 kW Plastic housing
18.5–400 kW Sheet metal housing
Three-phase 480 V
0.75–15 kW Plastic housing
18.5–400 kW Sheet metal housing
Three-phase 690 V
55–500 kW Sheet metal housing
2.3 Technical Specications
Table 2-2 Technical specications of the MD380
Item Specications
Standard
functions
Maximum frequency
Vector control: 0–300 Hz
V/F control: 0–3200 Hz
Carrier frequency
0.5–16 kHz
The carrier frequency is automatically adjusted based
on the load features.
Input frequency
resolution
Digital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
Control mode
Sensorless ux vector control (SFVC)
Closed-loop vector control (CLVC)
Voltage/Frequency (V/F) control
Startup torque
G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)
P type: 0.5 Hz/100%
Speed range
1:100 (SFVC)
1:1000 (CLVC)
Speed stability accuracy
± 0.5% (SFVC)
± 0.02% (CLVC)
Torque control accuracy
± 5% (CLVC)