MD380 User Manual Function Code Table
- 103 -
Function
Code
Parameter Name
Setting Range
Default Property
*URXS)2SHUDWLRQ3DQHODQG'LVSOD\
F7-01 MF.K Key function selection
0: MF.K key disabled
1: Switchover between
operation panel control and
remoteommand control (terminal
or communication)
2: Switchover between forward
rotation and reverse rotation
3: Forward jog
4: Reverse jog
0 ƾ
F7-02 67235(6(7NH\IXQFWLRQ
0: Stop function enabled only in
operation panel control
1: Stop function enabled in any
operation mode
1 ƿ
F7-03
LED display running
parameters 1
0000–FFFF
Bit00: Running frequency 1 (Hz)
Bit01: Frequency reference (Hz)
Bit02: Bus voltage (V)
%LW2XWSXWYROWDJH9
%LW2XWSXWFXUUHQW$
%LW2XWSXWSRZHUN:
%LW2XWSXWWRUTXH
Bit07: DI State
%LW'26WDWH
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit11: AI3 voltage (V)
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
Bit15: PID reference
1F ƿ
1F ƿ