Function Code Table
MD380 User Manual
- 106 -
Function
Code
Parameter Name
Setting Range
Default Property
Group F8: Auxiliary Functions
F8-00 Jog running frequency
0.00 Hz to maximum frequency
2.00 Hz ƿ
F8-01 Jog acceleration time
0.0–6500.0s
20.0s ƿ
F8-02 -RJ2*GHFHOHUDWLRQWLPH
0.0–6500.0s
20.0s ƿ
F8-03 Acceleration time 2
0.0–6500.0s
Model
dependent
ƿ
F8-04 Deceleration time 2
0.0–6500.0s
Model
dependent
ƿ
F8-05 Acceleration time 3
0.0–6500.0s
Model
dependent
ƿ
F8-06 Deceleration time 3
0.0–6500.0s
Model
dependent
ƿ
F8-07 Acceleration time 4
0.0–500.0s
Model
dependent
ƿ
F8-08 Deceleration time 4
0.0–6500.0s
Model
dependent
ƿ
F8-09 Frequency jump 1
0.00 Hz to maximum frequency
0.00 Hz ƿ
F8-10 Frequency jump 2
0.00 Hz to maximum frequency
0.00 Hz ƿ
F8-11 Frequency jump band
0.00 Hz to maximum frequency
0.00 Hz ƿ
F8-12
Forward/Reverse rotation
dead-zone time
0.0–3000.0s
0.0s ƿ
F8-13 Reverse control
0: Enabled
1: Disabled
0 ƿ
F8-14
Running mode when
frequency reference lower
than frequency lower limit
0: Run at frequency lower limit
1: Stop
2: Run at zero speed
0 ƿ
F8-15 Droop control
0.00–10.00 Hz
0.00 Hz ƿ
F8-16
Accumulative power-on time
threshold
0–65000 h
0 h ƿ
F8-17
Accumulative running time
threshold
0–65000 h
0 h ƿ
F8-18 Startup protection
0: Disabled
1: Enabled
0 ƿ
F8-19
Frequency detection value
(FDT1)
0.00 Hz to maximum frequency
50.00 Hz ƿ
F8-20
Frequency detection
hysteresis (FDT hysteresis 1)
0.0%–100.0% (FDT1 level)
5.0% ƿ
F8-21
Detection range of frequency
reached
0.00–100% (maximum frequency)
0.0% ƿ
efesotomasyon.com