MD380 User Manual Function Code Table
- 107 -
Function
Code
Parameter Name
Setting Range
Default Property
F8-22
Frequency jump during
acceleration/deceleration
0: Disabled
1: Enabled
0 ƿ
F8-25
Frequency switchover point
between acceleration time 1
and acceleration time 2
0.00 Hz to maximum frequency
0.00 Hz ƿ
F8-26
Frequency switchover point
between deceleration time 1
and deceleration time 2
0.00 Hz to maximum frequency
0.00 Hz ƿ
F8-27 Terminal jog preferred
0: Disabled
1: Enabled
0 ƿ
F8-28
Frequency detection value
(FDT2)
0.00 to maximum frequency
50.00 Hz ƿ
F8-29
Frequency detection
hysteresis (FDT hysteresis 2)
0.0%–100.0% (FDT2 level)
5.0% ƿ
F8-30
Detection value 1 of any
frequency reached
0.00 Hz to maximum frequency
50.00 Hz ƿ
F8-31
Detection amplitude of any
frequency reached
0.0%–100.0% (maximum
frequency)
0.0% ƿ
F8-32
Detection value 2 of any
frequency reached
0.00 Hz to maximum frequency
50.00 Hz ƿ
F8-33
Detection amplitude of any
frequency reached
0.0%–100.0% (maximum
frequency)
0.0% ƿ
F8-34 Zero current detection level
0.0%–300.0%
The value 100% corresponds to
the rated motor current
5.0% ƿ
F8-35
Zero current detection delay
time
0.01–600.00s
0.10s ƿ
F8-36 2XWSXWRYHUFXUUHQWWKUHVKROG
0.0% (no detection)
0.1%–300.0% (rated motor
current)
200.0% ƿ
F8-37
2XWSXWRYHUFXUUHQWGHWHFWLRQ
delay time
0.00–600.00s
0.00s ƿ
F8-38 Any current reaching 1
0.0%–300.0% (rated motor
current)
100.0% ƿ
F8-39
Any current reaching 1
amplitude
0.0%–300.0% (rated motor
current)
0.0% ƿ
F8-40 Any current reaching 2
0.0%–300.0% (rated motor
current)
100.0% ƿ
F8-41
Any current reaching 2
amplitude
0.0%–300.0% (rated motor
current)
0.0% ƿ
F8-42 Timing function
0: Disabled
1: Enabled
0 ƾ