Function Code Table
MD380 User Manual
- 108 -
Function
Code
Parameter Name
Setting Range
Default Property
F8-43 Timing duration source
0: F8-44
1: AI1
2: AI2
3: AI3
(100% of analog input corresponds
to the value of F8-44)
0 ƾ
F8-44 Timing duration
0.0–6500.0 min
0.0 min ƾ
F8-45 AI1 input voltage lower limit
0.00 V to F8-46
3.10 V ƿ
F8-46 AI1 input voltage upper limit
F8-45 to 10.00 V
6.80 V ƿ
F8-47
Module temperature
threshold
0°C–100°C
75
°C
ƿ
F8-48 Cooling fan working mode
:RUNLQJGXULQJUXQQLQJ
:RUNLQJFRQWLQXRXVO\
0 ƿ
F8-49 :DNHXSIUHTXHQF\
Hibernating frequency (F8-51) to
maximum frequency (F0-10)
0.00 Hz ƿ
F8-50 :DNHXSGHOD\WLPH
0.0–6500.0s
0.0s ƿ
F8-51 Hibernating frequency
0.00 Hz to wakeup frequency (F8-
49)
0.00 Hz ƿ
F8-52 Hibernating delay
0.0–6500.0s
0.0s ƿ
F8-53
Current running time
reached
0.0–6500.0 min
0.0 min ƿ
F8-54
2XWSXWSRZHUFRUUHFWLRQ
FRHI¿FLHQW
0.00%–200 .0%
100.0% ƿ