MD380 User Manual Function Code Table
- 117 -
Function
Code
Parameter Name
Setting Range
Default Property
*URXS)E:REEOHIXQFWLRQ)L[HG/HQJWKDQG&RXQW
Fb-00 :REEOHVHWWLQJPRGH
0: Relative to the central
frequency
1: Relative to the maximum
frequency
0 ƿ
Fb-01 :REEOHDPSOLWXGH
0.0%–100.0%
0.0% ƿ
Fb-02 :REEOHVWHS
0.0%–50.0%
0.0% ƿ
Fb-03 :REEOHF\FOH
0.0–3000.0s
10.0s ƿ
Fb-04
Triangular wave rising time
FRHI¿FLHQW
0.1%–100.0%
50.0% ƿ
Fb-05 Set length
0–65535 m
1000 m ƿ
Fb-06 Actual length
0–65535 m
0 m ƿ
Fb-07 Number of pulses per meter
0.1–6553.5
100.0 ƿ
Fb-08 Set count value
1–65535
1000 ƿ
Fb-09 Designated count value
1–65535
1000 ƿ
Group FC: Multi-Reference and Simple PLC Function
FC-00 Reference 0
-100.0%–100.0%
0.0% ƿ
FC-01 Reference 1
-100.0%–100.0%
0.0% ƿ
FC-02 Reference 2
-100.0%–100.0%
0.0% ƿ
FC-03 Reference 3
-100.0%–100.0%
0.0% ƿ
FC-04 Reference 4
-100.0%–100.0%
0.0% ƿ
FC-05 Reference 5
-100.0%–100.0%
0.0% ƿ
FC-06 Reference 6
-100.0%–100.0%
0.0% ƿ
FC-07 Reference 7
-100.0%–100.0%
0.0% ƿ
FC-08 Reference 8
-100.0%–100.0%
0.0% ƿ
FC-09 Reference 9
-100.0%–100.0%
0.0% ƿ
FC-10 Reference 10
-100.0%–100.0%
0.0% ƿ
FC-11 Reference 11
-100.0%–100.0%
0.0% ƿ
FC-12 Reference 12
-100.0%–100.0%
0.0% ƿ
FC-13 Reference 13
-100.0%–100.0%
0.0% ƿ
FC-14 Reference 14
-100.0%–100.0%
0.0% ƿ
FC-15 Reference 15
-100.0%–100.0%
0.0% ƿ
FC-16 Simple PLC running mode
0: Stop after running one cycle
.HHS¿QDOYDOXHVDIWHUUXQQLQJ
one cycle
2: Repeat after running one cycle
0 ƿ