Function Code Table
MD380 User Manual
- 118 -
Function
Code
Parameter Name
Setting Range
Default Property
FC-17
Simple PLC retentive
selection
8QLWVGLJLW5HWHQWLYHXSRQSRZHU
failure)
00 ƿ
0: No
1: Yes
Ten's digit (Retentive upon stop)
0: No
1: Yes
FC-18
Running time of simple PLC
reference 0
0.0–6553.5s (h)
0.0s (h) ƿ
FC-19
Acceleration/deceleration time
of simple PLC reference 0
0–3
0 ƿ
FC-20
Running time of simple PLC
reference 1
0.0–6553.5s (h)
0.0s (h) ƿ
FC-21
Acceleration/deceleration time
of simple PLC reference 1
0–3
0 ƿ
FC-22
Running time of simple PLC
reference 2
0.0–6553.5s (h)
0.0s (h) ƿ
FC-23
Acceleration/deceleration time
of simple PLC reference 2
0–3
0 ƿ
FC-24
Running time of simple PLC
reference 3
0.0–6553.5s (h)
0.0s (h) ƿ
FC-25
Acceleration/deceleration time
of simple PLC reference 3
0–3
0 ƿ
FC-26
Running time of simple PLC
reference 4
0.0–6553.5s (h)
0.0s (h) ƿ
FC-27
Acceleration/deceleration time
of simple PLC reference 4
0–3
0 ƿ
FC-28
Running time of simple PLC
reference 5
0.0–6553.5s (h)
0.0s (h) ƿ
FC-29
Acceleration/deceleration time
of simple PLC reference 5
0–3
0 ƿ
FC-30
Running time of simple PLC
reference 6
0.0–6553.5s (h)
0.0s (h) ƿ
FC-31
Acceleration/deceleration time
of simple PLC reference 6
0–3
0 ƿ
FC-32
Running time of simple PLC
reference 7
0.0–6553.5s (h)
0.0s (h) ƿ
FC-33
Acceleration/deceleration time
of simple PLC reference 7
0–3
0 ƿ
FC-34
Running time of simple PLC
reference 8
0.0–6553.5s (h)
0.0s (h) ƿ