Description of Function Codes
MD380 User Manual
- 150 -
Function Code Parameter Name Setting Range Default
F0-24
Motor parameter group
selection
0: Motor parameter group 1
1: Motor parameter group 2
0
The MD380 can drive two motors at different time. You can set the motor nameplate
parameters respectively, independent motor auto-tuning, different control modes, and
parameters related to running performance respectively for the two motors.
Motor parameter group 1 corresponds to groups F1 and F2. Motor parameter group 2
corresponds to group A2.
You can select the current motor parameter group by using F0-24 or perform switchover
between the motor parameter groups by means of a DI terminal. If motor parameters
selected by means of F0-24 conflict with those selected by means of DI terminal, the
selection by DI is preferred.
Function Code Parameter Name Setting Range Default
F0-25
Acceleration/Deceleration
time base frequency
0: Maximum frequency (F0-10)
1: Frequency reference
2: 100 Hz
0
The acceleration/deceleration time indicates the time for the AC drive to increase from 0
Hz to the frequency set in F0-25. If this parameter is set to 1, the acceleration/deceleration
time is related to the frequency reference. If the frequency reference changes frequently, the
motor's acceleration/deceleration also changes.
Function Code Parameter Name Setting Range Default
F0-26
%DVHIUHTXHQF\IRU83'2:1
PRGL¿FDWLRQGXULQJUXQQLQJ
0: Running frequency
1: Frequency reference
0
This parameter is valid only when the frequency source is digital setting.
It is used to set the base frequency to be modified by using keys
and or the
WHUPLQDO83'2:1IXQFWLRQ,IWKHUXQQLQJIUHTXHQF\DQGIUHTXHQF\UHIHUHQFHDUHGLIIHUHQW
there will be a large difference between the AC drive's performance during the acceleration/
deceleration process.
efesotomasyon.com