MD380 User Manual Desc
ription of Function Codes
- 153 -
Function Code Parameter Name Setting Range Default
F1-27 Encoder pulses per revolution 1–65535 1024
7KLVSDUDPHWHULVXVHGWRVHWWKHSXOVHVSHUUHYROXWLRQ335RI$%=RU89:LQFUHPHQWDO
encoder. In CLVC mode, the motor cannot run properly if this parameter is set incorrectly.
Function Code Parameter Name Setting Range Default
F1-28 Encoder type
0: ABZ incremental encoder
89:LQFUHPHQWDOHQFRGHU
2: Resolver
6,1&26HQFRGHU
:LUHVDYLQJ89:HQFRGHU
0
The MD380 supports multiple types of encoder. Different PG cards are required for
GLIIHUHQWW\SHVRIHQFRGHU6HOHFWWKHDSSURSULDWH3*FDUGIRUWKHHQFRGHUXVHG2QO\$%=
incremental encoder and resolver are applicable to asynchronous motor.
After installation of the PG card is complete, set this parameter properly based on the actual
FRQGLWLRQ2WKHUZLVHWKH$&GULYHFDQQRWUXQSURSHUO\
Function Code Parameter Name Setting Range Default
F1-30
A/B phase sequence of ABZ
incremental encoder
0: Forward
1: Reserve
0
7KLVSDUDPHWHULVYDOLGRQO\IRU$%=LQFUHPHQWDOHQFRGHU)DQGLVXVHGWRVHWWKH
A/B phase sequence of the ABZ incremental encoder.
It is valid for both asynchronous motor. The A/B phase sequence can be obtained through
"Asynchronous motor complete auto-tuning".
Function Code Parameter Name Setting Range Default
F1-31 Encoder installation angle
0.0°–359.9° 0.0°
Function Code Parameter Name Setting Range Default
F1-32
89:SKDVHVHTXHQFHRI89:
encoder
0: Forward
1: Reverse
0
F1-33 89:HQFRGHUDQJOHRIIVHW
0.0°–359.9° 0.0°
Function Code Parameter Name Setting Range Default
F1-34 Number of pole pairs of resolver 1–65535 1
If a resolver is applied, set the number of pole pairs properly.