EasyManuals Logo

Inovance MD380 Series User Manual

Inovance MD380 Series
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
Description of Function Codes
MD380 User Manual
- 154 -
Function Code Parameter Name Setting Range Default
F1-36
Encoder wire-break fault detection
time
0.0s: No action
0.1–10.0s
0.0s
This parameter is used to set the time that a wire-break fault lasts. If it is set to 0.0s, the
encoder wire-break fault is not detected. If the duration of the encoder wire-break fault
detected by the AC drive exceeds the time set in this parameter, the AC drive reports Err20.
Function Code Parameter Name Setting Range Default
F1-37
Auto-tuning
selection
0: No auto-tuning
1: Static auto-tuning 1
2: Dynamic auto-tuning
3: Static auto-tuning 2
0
 0: No auto-tuning
Auto-tuning is prohibited.
 1: Static auto-tuning 1
It is applicable to scenarios where dynamic auto-tuning cannot be performed because
the asynchronous motor cannot be disconnected from the large-inertia load.
 2: Dynamic auto-tuning
During the process of complete auto-tuning, the AC drive performs static auto-tuning
¿UVWDQGWKHQDFFHOHUDWHVWRRIWKHUDWHGPRWRUIUHTXHQF\ZLWKLQWKHDFFHOHUDWLRQ
time set in F0-17. The AC drive keeps running for a certain period and then decelerates
to stop within deceleration time set in F0-18.
 3: Static auto-tuning 2
It is applicable to scenarios without the encoder and is performed in the motor standstill
state. Be careful during the auto-tuning process becuase the motor may joggle slightly.
Note
Motor auto-tuning can be performed in operation panel control, terminal control and
communication control.
efesotomasyon.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD380 Series and is the answer not in the manual?

Inovance MD380 Series Specifications

General IconGeneral
BrandInovance
ModelMD380 Series
CategoryDC Drives
LanguageEnglish

Related product manuals