Function Code Parameter Name Setting Range Default
F9-49
Fault protection
action selection 3
8QLWVGLJLW8VHUGH¿QHGIDXOW(UU
00000
Same as unit's digit in F9-47
7HQVGLJLW8VHUGH¿QHGIDXOW(UU
Same as unit's digit in F9-47
Hundred's digit (Accumulative power-on time
reached, Err29)
Same as unit's digit in F9-47
Thousand's digit (Load becoming 0, Err30)
0: Coast to stop
1: Stop according to the stop mode
2: Continue to run at 7% of rated motor frequency
and restore to the frequency reference if the load
recovers
Ten thousand's digit (PID feedback lost during
running, Err31)
Same as unit's digit in F9-47
F9-50
Fault protection
action selection 4
8QLWVGLJLW7RRODUJHVSHHGIHHGEDFNHUURU(UU
00000
Same as unit's digit in F9-47
Ten's digit (Motor over-speed, Err43)
Same as unit's digit in F9-47
Hundred's digit (Initial position fault, Err51)
Same as unit's digit in F9-47
Thousand's digit (Speed feedback fault, Err52)
Same as unit's digit in F9-47
Ten thousand's digit: Reserved
If "Coast to stop" is selected, the AC drive displays Err** and directly stops.
 If "Stop according to the stop mode" is selected, the AC drive displays A** and stops
according to the stop mode. After stop, the AC drive displays Err**.
 If "Continue to run" is selected, the AC drive continues to run and displays A**. The
running frequency is set in F9-54.