MD380 User Manual EMC
- 255 -
,QVWDOODWLRQRI$&2XWSXW5HDFWRURQ3RZHU2XWSXW6LGH
:KHWKHUWRLQVWDOODQ$&RXWSXWUHDFWRURQWKHSRZHURXWSXWVLGHLVGHSHQGHQWRQWKH
actual situation. The cable connecting the AC drive and the motor should not be too long;
capacitance enlarges when an over-long cable is used and thus high-harmonics current
may be easily generated.
If the length of the output cable is equal to or greater than the value in the following table,
install an AC output reactor on the power output side of the AC drive.
Table 7-3 Cable length threshold when an AC output reactor is installed
AC Drive Power
N:
Rated Voltage
(V)
Cable Length Threshold
(m)
4 200–500 50
5.5 200–500 70
7.5 200–500 100
11 200–500 110
15 200–500 125
18.5 200–500 135
22 200–500 150
280–690 150
The following table lists the recommended manufacturer and models of AC output reactors.
Table 7-4 Recommended manufacturer and models of AC output reactors
AC Drive Model
5DWHG2XWSXW&XUUHQW
(A)
$&2XWSXW5HDFWRU0RGHO
(Inovance)
Three-phase 380–480 V, 50/60 Hz
MD380T0.7 2.1 0'2&/7
MD380T1.5 3.8 0'2&/7
MD380T2.2 5.1 0'2&/7
MD380T3.7 9 0'2&/7
MD380T5.5 13 0'2&/7
MD380T7.5 17 0'2&/7
MD380T11 25 0'2&/7
MD380T15 32 0'2&/7
MD380T18.5 37 0'2&/7
MD380T22 45 0'2&/7
MD380T30 60 0'2&/7
MD380T37 75 0'2&/7
MD380T45 91 0'2&/7
MD380T55 112 0'2&/7
MD380T75 150 0'2&/7
MD380T90 176 0'2&/7
efesotomasyon.com