4.8.9 Setting the Motor Rotating Direction
After you restore the default setting of the AC drive and press
RUN
, the direction in which
the AC drive drives the motor to run is regarded as the forward direction. If the rotating
direction is reverse to the direction required by the equipment, power off the AC drive and
H[FKDQJHDQ\WZRRIWKHRXWSXW89:FDEOHVZDLWXQWLOWKHPDLQFDSDFLWRURIWKH$&GULYHLV
completely discharged).
In applications where both forward rotation and reverse rotation are required, enable the
UHYHUVHFRQWURO)GHIDXOWYDOXHDQGPHDQZKLOHUHYHUVHWKHURWDWLQJGLUHFWLRQE\
setting F0-09 to 1. Then press
RUN
to make the motor rotate in the reverse direction, as
VKRZQLQWKHIROORZLQJ¿JXUH
Figure 4-26 Reverse the motor rotating direction
Command source
(operation panel control)
Forward rotation
command (terminal,
communication)
Reverse rotation
command
Fs > 0
Fs
0
Fs
0
Fs > 0
F0-09
0
0
1
1
0
1
F8-13
(terminal,
communication)
Frequency
reference
Rotating
direction setting
Reverse control
enabled
Forward
rotation
Reverse
rotation
Rotating
at 0.0 Hz
If the command source is terminal control and reverse rotation is required, use the default
value 0 of F8-13 to enable reverse control.
$FFRUGLQJWRWKHSUHFHGLQJ¿JXUHZKHQWKHIUHTXHQF\UHIHUHQFHRIWKH$&GULYHLVVHWE\
PHDQVRIFRPPXQLFDWLRQ)DQGUHYHUVHFRQWUROLVHQDEOHG)WKH$&
drive instructs the reverse direction if the frequency reference Fs is a negative value.
If the external command is reverse rotation or the frequency reference is a negative value,
EXWUHYHUVHFRQWUROLVGLVDEOHG) WKH$&GULYHZLOOUXQDW+]DQGKDVQRRXWSXW
In applications where reverse rotation is prohibited, do not change the rotating direction by
modifying the function codes because the function codes will be restored once the AC drive
restores the default settings.