MD380 User Manual Function Code Table
- 91 -
Function
Code
Parameter Name
Setting Range
Default Property
Group F2: Motor 1 Vector Control Parameters
F2-00
Speed loop proportional gain 1
1–100
30 ƿ
F2-01
Speed loop integral time 1
0.01–10.00s
0.50s ƿ
F2-02
Switchover frequency 1
0.00 to F2-05
5.00 Hz ƿ
F2-03
Speed loop proportional gain 2
1–100
20 ƿ
F2-04 Speed loop integral time 2
0.01–10.00s
1.00s ƿ
F2-05 Switchover frequency 2
F2-02 to maximum frequency
10.00 Hz ƿ
F2-06 Vector control slip gain
50%–200%
100% ƿ
F2-07
69&WRUTXH¿OWHUWLPH
constant
1–31
28 ƿ
F2-09
Torque upper limit source in
speed control mode
0: F2-10
1: AI1
2: AI2
3: AI3
4: Pulse reference (DI5)
5: Communication reference
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
100% of values 1 to 7
corresponds to F2-10.
0 ƿ
F2-10
Digital setting of torque
upper limit in speed control
mode
0.0%–200.0%
150.0% ƿ
F2-13
Excitation adjustment
proportional gain
0–60000
2000 ƿ
F2-14
Excitation adjustment
integral gain
0–60000
1300 ƿ
F2-15
Torque adjustment
proportional gain
0–60000
2000 ƿ
F2-16
Torque adjustment integral
gain
0–60000
1300 ƿ
F2-17 Speed loop integral property
8QLWVGLJLWLQWHJUDOVHSDUDWLRQ
0: Disabled
1: Enabled
0 ƿ